PLEASE NOTE
All Straumann compatible Bioconcept implant carriers are the traditional screw-retained design, NOT friction grip.
Contact Us for more information.
Straumann® Tissue Level Compatible (Bioconcept)
Showing all 12 results
-
-
Standard Implants
Standard Implants Ф 4.1 mm- L (Regular Neck Ф 4.8 mm)
Reference 013060
Condition: New
100% Straumann Tissue Level Compatible Bioconcept Standard Implant
Head Diameter: 4.8mm
Neck Height: 2.8mm
Surface: S-L-A 6mm
Outside diameter of implant thread: 4.1mm
Inside diameter of implant thread: 3.5mmSKU: 13000-13090 -
Standard Implants
Standard Implants Ф 4.8 mm- L (Regular Neck Ф 4.8 mm)
Reference 013120
Condition: New
100% Straumann Tissue Level Compatible Bioconcept Standard Implant
Head Diameter: 4.8mm
Neck Height: 2.8mm
Surface: S-L-A 6mm
Outside diameter of implant thread: 4.8mm
Inside diameter of implant thread: 4.2mmSKU: 13120-13160 -
Tapered Effect Implants
Ф 3.3mm Regular Neck
Reference 014010
Condition: New
Straumann Tissue Level Compatible Tapered Effect Implants
Products Code for Order: 014010
Head Diameter: 4.8mm
Neck Height: 1.8mm
Surface: S-L-A 8mm
Outside diameter of implant thread: 3.3mm
Inside diameter of implant thread: 2.8mmSKU: 14010-14040 -
-
Tapered Effect Implants
Ф 4.1 mm Regular Neck
Reference 014050
Condition: New
Straumann Tissue Level Compatible Tapered Effect Implants
Products Code for Order: 014050
Head Diameter: 4.8mm
Neck Height: 1.8mm
Surface: S-L-A 8mm
Outside diameter of implant thread: 4.1mm
Inside diameter of implant thread: 3.5mmSKU: 14050-14080 -
Standard Implants
Ф 4.8 mm (Wide Neck Ф 6.5 mm)
Reference 013170
Condition: New
100% Straumann Tissue Level Compatible Bioconcept Standard Implant
Head Diameter: 6.5mm
Neck Height: 2.8mm
Surface: S-L-A 6mm
Outside diameter of implant thread: 4.8mm
Inside diameter of implant thread: 4.2mmSKU: 13170-13200 -
Standard Plus Implants
Ф 4.8 mm Wide Neck
Reference 012150
Condition: New
Straumann Tissue Level Compatible Standard Plus Implants
Products Code for Order: 012150
Head Diameter: 6.5mm
Neck Height: 1.8mm
Surface: S-L-A 6mm
Outside diameter of implant thread: 4.8mm
Inside diameter of implant thread: 4.2mmSKU: 12150-12180 -
Tapered Effect Implants
Ф 4.8 mm Wide Neck
Reference 014090
Condition: New
Straumann Tissue Level Compatible Tapered Effect Implants
Products Code for Order: 014090
Head Diameter: 6.5mm
Neck Height: 1.8mm
Surface: S-L-A 10mm
Outside diameter of implant thread: 4.8mm
Inside diameter of implant thread: 4.2mmSKU: 14090-14110 -











